Guides, Specs, and Important URLs:
Product Type: Cable Modem
Model Name: DAZ8823A
Cable Type: Docsis 2.0
Port Standard(s): 10/100 with Full/Half Duplex and Auto Negotiation
Manufacturer's Website: http://www.toshiba.com/
Modem Page: http://www.toshiba.com/taisnpd/products/pcx2600.html
User Guide: http://www.toshiba.com/taisnpd/products/pcx2600_manual.pdf
Data Sheet: http://www.toshiba.com/taisnpd/products/PCX2600_datasheet.pdf
Screenshots: N/A
Modem Configuration Page Address(es): http://192.168.100.1/
Modem Default IP Address(es): 192.168.100.1
Connection Types:
Status Lights:
(Powering up - indicates when modem is first plugged into a power source)
(Normal use - indicates when the modem has finished initialization and is ready to allow an Internet connection)
- Cable Light
- Off (Powering up) - Modem has not finished initialization and not found downstream
- Off (Normal use) - No cable service to modem, check lines and possible ISP outages
- Flashing (Powering up) - Slow, once per second, flash indicates modem is searching for downstream
- Flashing (Powering up) - Fast or rapid flash indicates the modem is searching for the upstream
- Flashing (Normal use) - Fast and/or slow means the modem has lost the signal, likely bad signal levels or ISP outage
- On (Normal use) - Modem maintaining connection
- PC Light
- Off (Powering up) - Modem has not completed initialization
- Off (Normal use) - USB cable is not connected to Modem or PC
- Off (Normal use) - USB drivers are not installed on PC
- Off (Normal use) - Ethernet cable is not connected to Modem or PC
- On (Normal use) - USB drivers installed and connection is working
- On (Normal use) - Ethernet cable connection is working
- Data Light
- Off (Powering up) - Modem has not sync'd to ISP and no data transfer
- Off (Normal use) - No data transer to or from modem
- Flashing (Normal use) - Data being transfered and connection is working
- Test Light
- Off (Powering up & Normal use) - Modem has completed self test and working correctly
- Flashing (Powering up) - Modem is preforming self test
- On (Powering up & Normal use) - Modem has failed self test, likely bad modem and customer will need to contact Toshiba or place modem was purchased
- Power Light
- Off - Power cable is unplugged or plugged in non working electrical outlet
- On - Modem has power
Misc Notes:
- When working the lights will look like:
- Cable, PC, and Power lights will be solid green
- Data light will flash when accessing the Internet
- Normal Acceptable Signal Levels:
- TX (8 to 55)
- RX (-15 to 15) Ideal is 0
- SNR (Above 30)
- Main reasons for bad levels are too many splitters, loose connections, and damaged or low quality cables.
|